Case Study of the Compressive Strength, Concrete Covering and Sizes of Reinforced Concrete Columns for Condominium in Bangkok
Abstract
This research studies the compressive strength of concrete, concrete covering and size of
reinforced concrete columns and condominium in Bangkok. The construction quality control is
very good. Using PUNDIT non-destructive testing tools to determine the compressive strength of
reinforced concrete columns. Use the Micro Covermeter tool to find the concrete covering of the
columns and use the Accutap2 tool to find the height and cross-sectional dimensions of the four
columns of rectangular reinforced concrete columns. According to studies, it has been found that
"The strength of reinforced concrete columns in the post lower end was greater than the column
pieces of the percentage of 9.80 and column pieces on the lower column pieces central percent
to 1.93 and the compressive strength of concrete columns reinforced concrete in construction, the
average was higher than the 11.73 percent for building construction concrete covering virtually the
entire height of the reinforced concrete columns were very average, for concrete covering in steel
construction virtually the entire height of the reinforced concrete columns are averaged under a
predetermined value in construction by 1 percent and the size of the reinforced concrete columns
on four sides in the actual construction throughout the height of the columns precious, the
average larger than those used in the design 2.32 percent, respectively."