Show simple item record

dc.contributor.authorChusak Kereraten_US
dc.contributor.authorSupachai Thaipumen_US
dc.date.accessioned2017-03-13T08:08:30Z
dc.date.available2017-03-13T08:08:30Z
dc.date.issued2015
dc.identifier.urihttp://repository.rmutr.ac.th/123456789/491
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/491
dc.description.abstractThis study is to study a chloride in filtration into reinforced concrete structure in marine environment. The structure of case study located in Am phoeHuaHin and Amphoe Pranburi, and distance of this structure is not exceeding 10 km for from a sea. The powder of concrete is obtained from the structure as the representation. They were taken to titrate by mixing with silver nitrate solution and using acid a solvent follow by ASTM C1152 for determining total chloride content. According to the result, a maximum chloride is at a surface at structure and it will decrease along to the increasing depth. In case of concrete cracking, chloride will more increase that it cannot calculate by using the second Fick’s law. Moreover, the results showed that more strength and more age of concrete, coefficient of diffusion will be decrease. The structure in marine environment which located not exceed 1 km and 6 km far from sea in Amphoe HunHin and Amphoe Pranburi, respectively, found the chloride content of 1-25 kg/m3. Therefore, the structural design process should be considered damage due to chloride. However, the structure located more than 6 km far from sea, the structural design process is not necessary to consider the influence of chlorideen_US
dc.description.sponsorshipRajamangala University Of Technology Rattanakosinen_US
dc.language.isoTHen_US
dc.publisherRajamangala University Of Technology Rattanakosinen_US
dc.subjectChlorideen_US
dc.subjectReinforced concrete structureen_US
dc.subjectCoastal areasen_US
dc.titleChloride Content of Reinforced Concrete in Marine Environment. Case Study : HuaHin and PranBuri, PrachuapKhiri Khan Provinceen_US
dc.title.alternativeการแทรกซึมของคลอไรด์ในโครงสร้างคอนกรีตเสริมเหล็กที่ตั้งอยู่ในสภาพแวดล้อมทะเล กรณีศึกษา : อำเภอหัวหิน และอำเภอปราณบุรี จังหวัดประจวบคีรีขันธ์en_US
dc.typeResearchen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record