<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns="http://purl.org/rss/1.0/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dc="http://purl.org/dc/elements/1.1/">
<channel rdf:about="http://localhost:8080/xmlui/handle/123456789/903">
<title>การประชุมวิชาการระดับชาติมหาวิทยาลัยเทคโนโลยีราชมงคลรัตนโกสินทร์ ครั้งที่ 3 "การบูรณาการความรู้เพื่อสังคมที่ยั่งยืน" (The 3rd National RMUTR Conference : The Integration of Knowledge for Sustainable Society)</title>
<link>http://localhost:8080/xmlui/handle/123456789/903</link>
<description/>
<items>
<rdf:Seq>
<rdf:li rdf:resource="http://localhost:8080/xmlui/handle/123456789/1049"/>
<rdf:li rdf:resource="http://localhost:8080/xmlui/handle/123456789/928"/>
<rdf:li rdf:resource="http://localhost:8080/xmlui/handle/123456789/927"/>
<rdf:li rdf:resource="http://localhost:8080/xmlui/handle/123456789/926"/>
</rdf:Seq>
</items>
<dc:date>2026-04-12T20:37:46Z</dc:date>
</channel>
<item rdf:about="http://localhost:8080/xmlui/handle/123456789/1049">
<title>PID Controller Designs for Interacting Water Level Process</title>
<link>http://localhost:8080/xmlui/handle/123456789/1049</link>
<description>PID Controller Designs for Interacting Water Level Process
เรืองยศ เกตุรักษา; เจษฎาพร สถานทรัพย์; พิเชษฐ นาคนุ; สุดารัตน์ คำพร
This paper presents PID controller design for interacting water level process. The pressure transmitter is&#13;
used to sense the water level. Measurement of the pressure which the output is in the 4 -2 0  mA the voltage is&#13;
then converted into on   1 -5 volt analog signal to digital to digital converter, 16-bit arithmetic processing over&#13;
board Arduino Mega 2 5 6 0  to create a PID controller to turn on-off valve automatically. This project use a PID&#13;
controller design using Characteristic Ratio Assignment method (CRA) for coupled-tank process and use to meet&#13;
the prefect transient and steady-state response requirement.
</description>
<dc:date>2018-01-01T00:00:00Z</dc:date>
</item>
<item rdf:about="http://localhost:8080/xmlui/handle/123456789/928">
<title>A Development of Cyber Mini CNC Milling Machine 4 axes: part 1</title>
<link>http://localhost:8080/xmlui/handle/123456789/928</link>
<description>A Development of Cyber Mini CNC Milling Machine 4 axes: part 1
อดิศักดิ์ แข็งสาริกิจ
This paper presents a development of cyber mini CNC Milling Machine 4 axes. The purpose is to the CNC&#13;
operator can operate the CNC milling machines which operate the same pattern of work pieces. The research&#13;
consists of a structure of mini CNC milling machine 4 axes, microcontroller board, communications board and&#13;
website. The experiment, CNC operator can operate the mini CNC milling machine through the website. The&#13;
experimental results show the operation of mini CNC milling machine through the website. The research is&#13;
designed to define for 3 functions. There are RUN function, RESET function and PAUSE function. The results can&#13;
be operated the mini CNC milling machine and approached to develop.
</description>
<dc:date>2018-01-01T00:00:00Z</dc:date>
</item>
<item rdf:about="http://localhost:8080/xmlui/handle/123456789/927">
<title>Increasing Efficiency of Building Energy Utilization   A Case Study of Fuji Electric Manufacting (Thailand) Co.,Ltd.</title>
<link>http://localhost:8080/xmlui/handle/123456789/927</link>
<description>Increasing Efficiency of Building Energy Utilization   A Case Study of Fuji Electric Manufacting (Thailand) Co.,Ltd.
ทวิช คงธันร์
This study aims to optimize the use of energy in the building of Fuji Electric Manufacturing (Thailand) Co.,&#13;
Ltd. Building 2014 – 2016, the company had paid high costs of energy bills that contributes the study for&#13;
reducing electricity consumption by setting up a project to conserve electricity and to find ways for managing&#13;
high volumes of electricity.  A guideline for reducing electricity consumption was developed by considering 3&#13;
systems: Electrical equipment in the office, Lighting System and Air Conditioning System.  The study was carried&#13;
out by setting up energy committee, implementing a change in electrical equipment, and campaigning for&#13;
employees to participate in the reduction of electricity consumption. According to the policy of the Ministry of&#13;
Industry and the Energy Conservation Act 1992. According to the study, if can be observed that the amount of&#13;
electricity consumed could be reduced. Although there were some additional costs for replacing the equipment,&#13;
it would be worth for investment and can actually reduce electricity consumption according to the map.&#13;
Moreover the amount of electricity used within the company in 2017 was reduced by up to 12.5%.  Which was&#13;
higher than expectation of 10%.
</description>
<dc:date>2018-01-01T00:00:00Z</dc:date>
</item>
<item rdf:about="http://localhost:8080/xmlui/handle/123456789/926">
<title>The case study automated parking elevator control with Raspberry Pi</title>
<link>http://localhost:8080/xmlui/handle/123456789/926</link>
<description>The case study automated parking elevator control with Raspberry Pi
โสภณัฐ ชุนการุณ; อิศรา สวรรค์บัญชา; สัญญา สมัยมาก
This research presents an automated parking elevator control with Raspberry Pi board. The Raspberry pi&#13;
board was introduced to replace the PLC control system. The cost of producti on is lower and stable. The&#13;
application of microcontroller seri es Raspberry Pi and software Codesys Development System to control&#13;
operation. The test results were tested to meet the system objectives.
</description>
<dc:date>2018-01-01T00:00:00Z</dc:date>
</item>
</rdf:RDF>
